×÷ΪÖйúµÚÈý·½¼ì²âÓëÈÏÖ¤·þÎñµÄ¿ªÍØÕߺÍÁìÏÈÕߣ¬NG28ÄϹ¬28NGÏàÐÅÆ·ÅÆÁ¦Á¿¼ì²âΪȫÇò¿Í»§Ìṩһվʽ¼ìÑé¡¢²âÊÔ¡¢Ð£×¼¡¢ÈÏÖ¤¼°¼¼Êõ·þÎñ¡£
·þÎñÄÜÁ¦ÒÑÈ«ÃæÁýÕÖµ½·ÄÖ¯·þ×°¼°Ð¬°ü¡¢Ó¤Í¯Íæ¾ß¼°¼Ò¾ÓÉú»î¡¢µç×ÓµçÆ÷¡¢Ò½Ñ§½¡¿µ¡¢Ê³Æ·¼°Å©²úÎï……µÈÐÐÒµµÄ¹©Ó¦Á´ÉÏÏÂÓΡ£
È«Ãæ±£ÕÏÆ·ÖÊÓëÄþ¾²£¬Íƶ¯ºÏ¹æÓ봴У¬ÕÃÏÔÆ·ÅƾºÕùÁ¦£¬ÊµÏÖ¸ü¸ßÖÊÁ¿¡¢¸ü½¡¿µ¡¢¸üÄþ¾²¡¢¸üÂÌÉ«µÄ¿ÉÁ¬ÐøÉú³¤¡£
Ê×Ò³ > ÎÒÃǵķþÎñ > Ò½Ò©¼°Ò½Ñ§·þÎñ > Ò½ÁÆÆ÷е¼ì²â > ·þÎñÏêÇé
NG28ÄϹ¬28NGÏàÐÅÆ·ÅÆÁ¦Á¿¼ì²âΪȫÇòÓÐÔ´Ò½ÁÆÆ÷е¿Í»§Ìṩһվʽ²âÊÔ¡¢¼ìÑé¡¢ÈÏÖ¤¡¢ÉóºË¡¢Åàѵ¼°¼¼Êõ·þÎñ£¬°üÂÞÒ½ÓÃÕï²ìºÍ¼à»¤¡¢¼±¾È¡¢ÎïÀíÖÎÁÆ¡¢Ïû¶¾Ãð¾ú¡¢¿µ¸´¡¢ÁÙ´²¼ìÑéÉ豸µÈÓÐÔ´Ò½ÁÆÆ÷е°²¹æ¡¢EMC¡¢µç´Å¼æÈÝ¡¢¿É¿¿ÐÔ¡¢ÀÏ»¯µÈÓÐÔ´Ò½ÁÆÆ÷еע²áµÄÄþ¾²ÐÔ¡¢ÓÐЧÐÔÑо¿µÈһվʽ½â¾ö·½°¸¡£
ÒÀ¾Ý¡¶Ò½ÁÆÆ÷еע²á¹ÜÀí´ëÊ©¡·£¨¾ÖÁîµÚ16ºÅ£©ÖеĹ涨£¬µÚ¶þÀà¡¢µÚÈýÀàÒ½ÁÆÆ÷еÓɹú¼ÒʳƷҩƷ¼à¶½¹ÜÀí¾Ö»áͬ¹ú¼ÒÖÊÁ¿¼à¶½¼ìÑé¼ìÒß×ܾÖÈϿɵÄÒ½ÁÆÆ÷е¼ì²â»ú¹¹½øÐÐ×¢²á¼ì²â£¬Ò½ÁÆÆ÷е¼ì²â»ú¹¹Ó¦µ±ÔÚ¹ú¼ÒʳƷҩƷ¼à¶½¹ÜÀí¾ÖºÍ¹ú¼ÒÖÊÁ¿¼à¶½¼ìÑé¼ìÒß×ܾÖÈϿɵļì²â·¶Î§ÄÚ£¬ÒÀ¾ÝÉú²úÆóÒµÉ걨ÊÊÓõIJúÎï³ß¶È£¨°üÂÞÊÊÓõĹú¼Ò³ß¶È¡¢ÐÐÒµ³ß¶È»òÕßÉú²úÆóÒµÖƶ¨µÄ×¢²á²úÎï³ß¶È£©¶ÔÉ걨²úÎï½øÐÐ×¢²á¼ì²â£¬²¢³ö¾ß¼ì²â³ÂËߣ¬·½¿ÉÓÃÓÚÁÙ´²ÊÔÑé»òÕßÉêÇë×¢²á¡£
×¢²á¼ì²â×÷ΪҽÁÆÆ÷еע²á¹ý³ÌÖÐÖØÒªµÄÒ»»·£¬ÆäÄ¿µÄÊÇΪÁËÑéÖ¤Ò½ÁÆÆ÷е²úÎïµÄÐÔÄÜÒªÇó¼°Äþ¾²ÒªÇóÊÇ·ñÇкϲúÎï×¢²á³ß¶È£¨»ò¹ú¼Ò³ß¶È¡¢ÐÐÒµ³ß¶È£©µÄ¹æ¶¨£¬±£Ö¤²úÎïµÄÓÐЧÐÔÄܺÍʹÓÃÄþ¾²¡£Ö»ÓÐͨ¹ýÁË×¢²á¼ì²âµÄ²úÎ·½¿É½øÐÐÏÂÒ»²½µÄÁÙ´²ÊÔÑéºÍ×îÖյIJúÎï×¢²á¡£
1¡¢Ò½ÓÃÕï²ìºÍ¼à»¤Æ÷е£º¶à²ÎÊý¼à»¤ÒÇ¡¢Ðĵçͼ»ú¡¢Âö²«ÑªÑõÒÇ¡¢ÑªÑ¹¼Æ¡¢µç×ӺͺìÍâÌåμÆ
2¡¢ºôÎü¡¢Âé×íºÍ¼±¾ÈÆ÷е£º¼ÒÓúôÎü»ú¡¢Ò½Ó÷Ö×ÓɸÖÆÑõ»ú¡¢¼ÒÓ÷Ö×ÓɸÖÆÑõ»ú¡¢Ð¡ÐÍÒ½ÓÃÖÆÑõ»ú¡¢±ãЯʽÖÆÑõ»ú¡¢Ò½ÓÃÑõÆøŨËõÆ÷¡¢Ò½Óó¬ÉùÎí»¯Æ÷¡¢Ò½ÓÃѹËõʽÎí»¯Æ÷¡¢Ò½ÓÃÎí»¯Æ÷
3¡¢ÎïÀíÖÎÁÆÆ÷е£ºÉñ¾ºÍ¼¡Èâ´Ì¼¤Æ÷¡¢µÍƵµçÁÆÒÇ¡¢ÖеÍƵÖÎÁÆÒÇ¡¢ÈȵæʽÖÎÁÆÒÇ¡¢Ìض¨µç´Å²¨ÖÎÁÆÒÇ¡¢Ô¶ºìÍâ·øÉäÖÎÁÆÒÇ¡¢ºìÍâÈÈ·øÉäÀíÁƵơ¢Ìض¨µç´Å²¨ÖÎÁÆÆ÷¡¢µçλÖÎÁÆÉ豸¡¢ºì¹âÖÎÁÆÉ豸¡¢×ÏÍâÖÎÁÆÉ豸
4¡¢Ò½ÁÆÆ÷еÏû¶¾Ãð¾úÆ÷е£ºÒ½ÓÃÇåÏ´Æ÷¡¢Ò½Óó¬Éù²¨ÇåÏ´Æ÷×¢Êä¡¢»¤ÀíºÍ·À»¤Æ÷е£ºÒ½Ó÷À»¤¿ÚÕÖ¡¢Ò½ÓÃÍâ¿Æ¿ÚÕÖ¡¢Ò»´ÎÐÔʹÓÃÒ½ÓÿÚÕÖ¡¢ÈÕ³£·À»¤ÐÍ¿ÚÕÖ¡¢ºôÎü·À»¤ ×ÔÎü¹ýÂËʽ·À¿ÅÁ£ÎïºôÎüÆ÷¡¢¶ùͯ¿ÚÕÖ¡¢ÕëÖ¯¿ÚÕÖ
5¡¢»¼Õß³ÐÔØÆ÷е£ºÊÖ¶¯²¡´²¡¢µç¶¯²¡´²
6¡¢Ò½Óÿµ¸´Æ÷е£ºÖúÌýÆ÷¡¢ÊÖ¶¯ÂÖÒγµ
7¡¢ÁÙ´²¼ìÑéÉ豸£ºÀëÐÄ»ú¡¢ºËËáÌáÈ¡ÒÇ¡¢È«×Ô¶¯ºËËáÌáÈ¡ÒÇ¡¢È«×Ô¶¯ºËËá´¿»¯ÒÇ¡¢È«×Ô¶¯ºËËáÌáÈ¡´¿»¯ÒÇ¡¢Ò½ÓÃÀä²ØÏä¡¢Ò½ÓÃÀ䶳Ïä¡¢Ò½ÓÃÀä²ØÀ䶳Ïä¡¢Ò½Óó¬µÍÎÂÀ䶳Ïä¡¢ÑùÆ·Ç°´¦ÖÃϵͳ¡¢ÑùÆ·¼ì²é×Ô¶¯»¯ÏµÍ³¡¢È«×Ô¶¯ÑùÆ·´¦ÖÃϵͳ¡¢ÑùÆ·ºó´¦ÖÃϵͳ¡¢·Ö±´¦ÖÃϵͳ¡¢Ñù±¾´¦Öü°·õÓýϵͳ
7¡¢Ò½ÓÃÈí¼þ£ºÌåÍâÕï¶ÏÀàÈí¼þµÈ
Ãû³Æ/Title |
¹ú¼Ê³ß¶È/international standards |
¹úÄڳ߶È/National standards |
ÕÉÁ¿¡¢¿ØÖƺÍÊÔÑéÊÒÓõçÆøÉ豸µÄÄþ¾²ÒªÇó Electrical Equipment For Measurement, |
IEC/EN 61010-1 |
GB4793.1 |
ÕÉÁ¿¡¢¿ØÖƺÍÊÔÑéÊÒÓõçÆøÉ豸µÄÄþ¾²ÒªÇó Safety requirements for electrical equipment for measurement, control andlaboratory use –Part 2-101: Particular requirements for in vitro diagnostic (IVD) medicalequipm |
IEC/EN 61010-2-101
|
YY 0648 |
ÕÉÁ¿¡¢¿ØÖƺÍʵÑéÊÒÓõçÆøÉ豸µÄÄþ¾²ÒªÇó£ºÊµÑéÊÒÓ÷ÖÎöºÍÆäËûÄ¿µÄ×Ô¶¯ºÍ°ë×Ô¶¯É豸µÄÌØÊâÒªÇó Safety requirements for electrical equipment for measurement, control and laboratory use – Part 081: Particular requirements for automatic and semiautomatic laboratory equipment for analysis and other purposes |
IEC/EN 61010-2-081
|
GB4793.9 GB/T42125.14 |
ÕÉÁ¿¡¢¿ØÖƺÍʵÑéÊÒÓõĵçÉ豸 µç´Å¼æÈÝÐÔÒªÇó µÚ1²¿ÃÅ:ͨÓÃÒªÇó Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
IEC/EN 61326-1
|
GB/T 18268.1 |
ÕÉÁ¿¡¢¿ØÖƺÍʵÑéÊÒÓõçÉ豸.µç´Å¼æÈÝÐÔ(EMC)µÄÒªÇó.ÌØÊâÒªÇó.ʵÑéÊÒÕï¶Ï Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
IEC/EN 61326-2-6
|
GB/T18268.26 |
Ãû³Æ |
¹ú¼Ê³ß¶È |
¹úÄÚ³ß¶È |
Ò½ÓõçÆøÉ豸 µÚ2²¿ÃÅ Ðĵçͼ»úÄþ¾²×¨ÓÃÒªÇó Medical safety and electrical essential equipment performance - Part 2-25: of electrocardiographs Particular requirements |
IEC/EN 60601-2-25 |
GB 10793 |
ÎÞ´´ÑªÑ¹¼ÆµÚ1²¿ÃÅ:ͨÓÃÒªÇó Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement type |
EN ISO /ISO 81060-1 |
|
ÎÞ´´ÑªÑ¹¼Æ.µÚ3²¿ÃÅ:µç-»úѪѹÕÉÁ¿ÏµÍ³µÄÔö²¹ÒªÇó Non-invasive sphygmomanometers - Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems |
EN 1060-3
|
|
Ò½ÓõçÆøÉ豸 µÚ2-27²¿ÃÅ£ºÐĵç¼à»¤Äþ¾²¼°»ùÌìÐÔÄÜרÓÃÒªÇó Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment |
IEC/EN 60601-2-27
|
GB 9706.25 |
Ò½ÓõçÆøÉ豸 µÚ2-26²¿ÃÅ£ºÄÔµçͼ»úÄþ¾²×¨ÓÃÒªÇó Medical electrical equipment-Part 2-26: Particular requirements for the safety of electroencephalographs |
IEC/EN 60601-2-26:2012 |
GB 9706.26 |
Ò½ÓõçÆøÉ豸 µÚ2-56²¿ÃÅ:ÁÙ´²ÌåμƵĻù±¾Äþ¾²ºÍÐÔÄܵÄרÓÃÒªÇó Medical safety and electrical essential equipment-Part performance2-56: of clinical Particular thermometers requirements for basic body temperature measurement |
ISO/ EN ISO 80601-2-56 |
YY 9706.256 |
Ѫѹ¼Æ Non-invasive automated sphygmomanometers |
ANSI/AAMI SP10 |
YY 0670 |
Ò½ÓõçÆøÉ豸--µÚ2-57²¿ÃÅ:ÖÎÁÆ¡¢Õï¶Ï¡¢¼à²âºÍÃÀÈÝ/ÃÀѧʹÓõķǼ¤¹â¹âÔ´É豸µÄ»ù±¾Äþ¾²ºÍ»ùÌìÐÔÄÜרÓÃÒªÇó Medical electrical equipment - Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic,diagnostic,monitoring and cosmetic/aesthetic use |
IEC/EN 60601-2-57
|
YY 9706.257 |
Ò½ÓõçÆøÉ豸 µÚ2-2²¿ÃÅ:¸ßƵÊÖÊõÉ豸Äþ¾²×¨ÓÃÒªÇó Medical Basic Safety Electrical And Equipment Essential -Performance Part 2-2: Particular Of High Requirements Frequency For Surgical Equipment And High Frequency Surgical Accessories |
IEC/EN/EN IEC 60601-2-2 |
GB 9706.4 |
Ò½ÓõçÆøÉ豸µÚ1²¿ÃÅ£ºÄþ¾²Í¨ÓÃÒªÇó Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
ANSI/AAMI ES60601-1 |
GB9706.1 |
Ò½ÓõçÆøÉ豸µÚ2-10²¿ÃÅ:Éñ¾ºÍ¼¡Èâ´Ì¼¤Æ÷Äþ¾²×¨ÓÃÒªÇó Medical electrical equipment - Part 2-10 : particular requirements for the safety of nerve and muscle stimulators |
IEC/EN 60601-2-10
|
YY 0607 |
Ò½ÓõçÆøÉ豸 µÚ2-30²¿ÃÅ:×Ô¶¯Ñ»·ÎÞ´´ÑªÑ¹¼à»¤É豸µÄÄþ¾²ºÍ»ùÌìÐÔÄÜרÓÃÒªÇó Medical electrical equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers |
|
YY 0667 |
Ò½ÓõçÆøÉ豸 µÚ2-49²¿ÃÅ£º¶à²ÎÊý»¼Õ߼໤É豸Äþ¾²×¨ÓÃÒªÇó Medical electrical equipment-Part 2-49:Particular requiremens for the safety of multifunction patient monitoring equipment |
IEC/EN 80601-2-49 |
YY 0668 |
Ò½ÓõçÆøÉ豸.Ò½ÓÃÂö²«ÑªÑõÒÇÉ豸»ù±¾Äþ¾²ºÍÖ÷ÒªÐÔÄÜרÓÃÒªÇó Medical electrical equipment — Part 2-61: Particular requirements for basic safetyand essential performance of pulseoximeter equipment |
ISO / EN ISO 80601-2-61
|
YY 0784 |
Ò½ÓõçÆøÉ豸 µÚ2-38²¿ÃÅ:Ò½Ôºµç¶¯´²Äþ¾²×¨ÓÃÒªÇó Medical electrical equipment - Part 2: Particular requirements for the safety of electrically operated hospital beds |
IEC/EN 60601-2-52
|
YY 0571 |
ÐĵçÕï¶ÏÉ豸 Diagnostic electrocardiographic devices |
ANSI/AAMI EC11 |
YY 1139 |
Ò½ÓõçÆøÉ豸 µÚ1-11²¿ÃÅ£ºÄþ¾²¼°»ùÌìÐÔÄܵÄͨÓÃÒªÇó—²¢Áг߶ȣº¼ÒÍ¥Ò½ÁƱ£½¡»·¾³ÏÂʹÓõÄÒ½ÓõçÆøÉ豸ºÍϵͳ Part 1-11: General requirements for basic safety and essential performance –Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment |
IEC/EN 60601-1-11
|
YY 9706.111 |
Ò½ÓÃÌåμÆ.×î´ó×°ÖÃСÐ͵çÌåμÆ(·ÇÔ¤²âÐͺÍÔ¤²âÐÍ)µÄÐÔÄÜ Performance of compact electrical thermometers (non-predictive and predictive) with maximum device |
EN 12470-3 |
|
ÁÙ´²ÌåμÆ.Á¬ÐøÕÉÁ¿Óõç×ÓÌåμƵÄÐÔÄÜ Performance of electrical thermometers |
EN 12470-4 |
YY 0785 |
ºìÍâÌåÎÂ¼Æ infrared ear thermometers (with maximum device) |
EN 12470-5 |
GB/T 21417.1 |
Ò½ÓõçÆøÉ豸 µÚ2²¿ÃÅ£º¶¯Ì¬ÐĵçͼϵͳÄþ¾²ºÍ»ùÌìÐÔÄÜרÓÃÒªÇó Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems |
IEC/EN 60601-2-47 |
YY 0885 |
Ò½ÓõçÆøÉ豸 µÚ2²¿ÃÅ£ºÕï¶ÏºÍÖÎÁƼ¤¹âÉ豸Äþ¾²×¨ÓÃÒªÇó Part 2-22: Particular requirements for basic safety and essential performance of surgical,cosmetic,therapeutic and diagnostic laser equipment |
IEC/EN 60601-2-22
|
GB 9706.20 |
Ò½ÓõçÆøÉ豸.µÚ2²¿ÃÅ:ÊÖÊõÎÞÓ°µÆºÍÕï¶ÏÓÃÕÕÃ÷µÆÄþ¾²×¨ÓÃÒªÇó Part 2-41: Particular requirements for the basic safety and essential performance of surgical luminaires and luminaires for diagnosis |
IEC/EN 60601-2-41 |
YY 0627 |
Ò½ÓõçÆøÉ豸 µÚ2²¿ÃÅ£ºÊÖÊǫ̃Äþ¾²×¨ÓÃÒªÇó Part 2-46: Particular requirements for the basic safety and essential performance of operating tables |
IEC/EN 60601-2-46
|
YY 0570 |
Ðĵç¼à»¤ÒǵçÀº͵¼ÁªÏß ECG trunk cables and patient leadwires |
AAMI ANSI EC53 |
YY 0828 |
Ò½ÓõçÆøÉ豸 µÚ2-18²¿ÃÅ:ÄÚ¿ú¾µÉ豸Äþ¾²×¨ÓÃÒªÇó Part performance 2-18: Particular of endoscopic requirements equipment |
IEC/EN 60601-2-18
|
GB9706.19 |
Ò½ÓõçÆøÉ豸 µÚ1-2 ²¿ÃÅ£ºÄþ¾²Í¨ÓÃÒªÇó ²¢Áг߶ȣºµç´Å¼æÈÝ ÒªÇóºÍÊÔÑé Medical electrical equipment-Part 1-2:General requirements for safetyCollateral standard :Electromagnetic compatibility-Requirements and tests |
IEC/EN 60601-1-2
|
YY 0505 YY9706.102 |
Ò½ÓõçÆøÉ豸 - µÚ1-8 ²¿ÃÅ:»ù±¾Äþ¾²ºÍ»ùÌìÐÔÄܵÄͨÓÃÒªÇó - ²¢Áг߶È: ͨÓÃÒªÇó£¬Ò½ÁƵçÆøÉ豸ºÍÒ½ÁƵçÆøϵÖÐͳ±¨¾¯ÏµÍ³µÄ²âÊÔºÍÖ¸ÄÏ Medical electrical equipment- Part 1-8: General requirements for safety Collateral standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems |
IEC/EN 60601-1-8
|
YY0709 |
¼¤¹â²úÎïµÄÄþ¾² µÚ1 ²¿ÃÅ:É豸·ÖÀàºÍÒªÇó Safety of laser products —Part 1: Equipment classification and requirements |
IEC/EN 60825-1 AS/NZS 2211.1 |
GB 7247.1 |
µÆºÍµÆϵͳµÄ¹âÉúÎïÄþ¾²ÐÔ Photobiological safety of lamps and lamp systems |
IEC /EN62471 |
GB/T 20145 |
ºôÎüÖÎÁÆÉ豸,µÚ1²¿ÃÅ:Îí»¯ÏµÍ³¼°Æä×é³É²¿ÃÅRESPIRATORY THERAPY EQUIPMENT –Part 1: Nebulizing systems and their components |
EN13544-1 |
YY 0109 |
Ò½ÓõçÆøÉ豸--µÚ2-24²¿ÃÅ:ÊäÒº±Ã¼°¿ØÖÆÆ÷µÄ»ù±¾Äþ¾²ºÍ»ùÌìÐÔÄÜרÓÃÒªÇó Medical electrical equipment –Part 2-24: Particular requirements for the basic safety and essential performance of infusion pumps and controllers |
IEC/EN 60601-2-24
|
GB 9706.27 |
Ò½ÓõçÆøÉ豸--µÚ2-34²¿ÃÅ:Óд´ÑªÑ¹¼à»¤É豸µÄ»ù±¾Äþ¾²ºÍ»ùÌìÐÔÄÜרÓÃÒªÇó Medical electrical equipment - Part 2-34: Particular requirementsfor the basic safety and essential performance of invasive bloodpressure monitoring equipment |
IEC/EN 60601-2-34
|
YY0783 |
Ò½ÓõçÆøÉ豸 2-60²¿ÃÅ£ºÑÀ¿ÆÉ豸µÄ»ù±¾Äþ¾²ºÍ»ùÌìÐÔÄÜ Medical electrical equipment –Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment |
IEC/EN 80601-2-60
|
GB 9706.260 |
Ò½ÓÃÉ豸 - µÚÒ»²¿ÃÅ£ºÒ½ÓÃÉ豸¿ÉÓÃÐÔ¹¤³ÌµÄÓ¦Óà Medical devices IEC devices 62366-1: - Part 2015 1: IEC Application 62366: 2007+A1:2014 of usability engineering |
IEC/EN 62366-1
|
YY/T 1474 |
Ò½ÓõçÆøÉ豸 - µÚ1-6²¿ÃÅ£º»ù±¾Äþ¾²ºÍ»ùÌìÐÔÄܵÄͨÓÃÒªÇó - ²¢Áг߶ȣº¿ÉÓÃÐÔ Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral s tandard: Usability |
IEC/EN 60601-1-6
|
YY/T 9706.106 |
Ò½ÓõçÆøÉ豸 µÚ2²¿ÃÅ:Ó¤¶ùÅàÑøÏäÄþ¾²×¨ÓÃÒªÇó Medical electrical equipment -Part 2:Particular requirements for safety of baby incubators |
IEC/EN 60601-2-19
|
GB 9706.219 |
Ò½ÁƵçÆøÉ豸-µÚ1-9²¿ÃÅ:»ù±¾Äþ¾²ºÍÖØÒªÐÔÄܵÄÒ»°ãÒªÇó.Á¥Êô³ß¶È:»·¾³ÒâʶÉè¼ÆµÄÒªÇó Medical electrical equipment Part 1-9: General requirements for basic safety and essential performance – Collateral Standard: Requirements for environmentally conscious design |
IEC/EN 60601-1-9
|
|
Ò½Óõç×ÓÌåÎÂ¼Æ Clinical electronic thermometer |
|
GB/T21416 |
Ò½ÁÆÆ÷еÈí¼þ Èí¼þÉú´æÖÜÆÚ¹ý³Ì Medical device software — Software life cycle processes |
IEC62304
|
YY/T 0664 |
Ò½ÓÃÎüÒýÉ豸 µÚ1²¿ÃÅ: µç¶¯ÎüÒýÉ豸 Äþ¾²ÒªÇó Medical suction equipment Part 1: Electrically powered suction equipment — Safety requirements |
ISO10079-1
|
YY/T 0636.1 |
Ò½ÓõçÆøÉ豸 µÚ2-37²¿ÃÅ£º³¬ÉùÒ½ÁÆÕï¶Ï¼àÊÓÉ豸»ù±¾Äþ¾²ºÍ»ùÌìÐÔÄܵÄÌØÊâÒªÇó Medical electrical equipment —Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment |
IEC/EN 60601-2-37 |
GB 9706.9 |
Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment Ò½Óó¬ÉùÕï¶ÏÉ豸ÉùÊä³öÐû²¼ÒªÇó
|
IEC 61157 |
GB/T16846 |
Ò½ÁÆÕï¶Ï³¬Éù²¨É豸µÄÉùÊä³ö³ÂËßÓó߶ÈÒªÁì Ultrasonics dental descaler systems; measurement and declaration of the output characteristics |
IEC 61205 |
YY/T 0751 |
³¬Éù¶àÆÕÀÕÌ¥¶ùÐÄÂÊÒÇ ultrasonic Doppler fetal heartbeat detector |
|
YY 0448 |
³¬Éù¶àÆÕÀÕÌ¥¶ù¼à»¤ÒÇ ultrasonic Doppler fetal monitor |
|
YY/T0449 |
³¬ÉùÀíÁÆÉ豸 Medical electrical equipment —Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment |
IEC/EN 60601-2-5 |
YY/T1090 |
³¬Éù Ë®ÌýÆ÷ µÚ1²¿ÃÅ£º40MHz ÒÔÏÂÒ½Óó¬Éù³¡µÄÕÉÁ¿ºÍÌØÕ÷Ãè»æ ultrasonic-Hydrophone Part 1: Measurement and characterization of medical ultrasonic fields to 40MHZ |
IEC62127-1 |
YY/T 0865.1 |
Ò½ÓÃÄÚ¿ú¾µ |
IEC/EN 60601-2-18 |
YY 0068.1, YY 0068.2, YY/T 0068.3 ,YY 0068.4 |
Ò½ÓýºÄÒʽÄÚ¿ú¾µ |
|
YY 1298 |
Ò½ÓÃÄÚ¿ú¾µÕÕÃ÷ÓùâÀ |
|
YY/T 0763 |
Ò½Óõç×ÓÄÚ¿ú¾µ |
|
YY 1587 |
Ò½ÓÃÄÚ¿ú¾µ ÄÚ¿ú¾µ¹¦Ð§¹©Ó¦×°Öà ÉãÏñϵͳ |
|
YY/T1603 |
»·¾³ÊÔÑéÒªÇó¼°ÊÔÑéÒªÁì |
|
GB/T14710 |
²úÎï¼ÓËÙÀÏ»¯ÊÔÑéÒªÁì |
IEC62506 |
GB/T34986 |
±ãЯʽºÍ±ãЯʽװÖÃÓÃÃܷ⺬¼îÐÔµç½âÒº¶þ´Îµç³ØµÄÄþ¾²ÒªÇó Secondary cells and batteries containing alkaline or other non-acid electrolytes- Safety requirements for portable sealed secondary cells,and for batteries made from them,for use in portable applications |
IEC/EN 62133 |
GB31241 |
ÁªºÏ¹ú¡¶¹ØÓÚΣÏÕ»õÎïÔËÊäµÄ½¨ÒéÊé ³ß¶ÈÓëÊÔÑéÊֲᡷ38.3 Õ recommendations on the transportation of dangerous goods manual of tests and criteria |
UN DOT 38.3 |
|
¼ÒÓúÍÀàËÆÓÃ;µçÆ÷µÄÄþ¾² ¿ÚÇ»ÎÀÉúÆ÷¾ßµÄÌØÊâÒªÇó Household and similar electrical appliances- Safety Particular requirements for for oral and hygiene appliances |
IEC/EN60335-2-52 |
GB 4706.59 |
¼ÒÓúÍÀàËÆÓÃ;µçÆ÷µÄÄþ¾²¼ÓʪÆ÷µÄÌØÊâÒªÇó Household and similar electrical appliances - Safety - Particular requirements for humidifiers |
IEC/EN 60335-2-98 |
GB 4706.48 |
¼ÒÓúÍÀàËÆÓÃ;µçÆ÷µÄÄþ¾²ÍÆÄÃÆ÷¾ßµÄÌØÊâÒªÇó Household and similar electrical appliances - Safety - Particular requirements for massage appliances |
IEC/EN 60335-2-32 |
GB 4706.10
|
¼ÒÓúÍÀàËÆÓÃ;µçÆ÷µÄÄþ¾² ů½ÅÆ÷ºÍÈȽŵæµÄÌØÊâÒªÇó Household and similar electrical appliances - Safety - Particular requirements for foot warmers and heating mats |
IEC/EN60335-2-81 |
GB4706.80
|
¼ÒÓúÍÀàËÆÓÃ;µçÆ÷µÄÄþ¾²×ÏÍâÏߺͺìÍâÏß·øÉäƤ·ôÆ÷¾ß µÄÌØÊâÒªÇó Household and similar electrical appliances - Safety - Particular requirements for appliances for skin exposure to optical radiation |
IEC/EN 60335-2-27
|
GB4706.85
|
¼ÒÓúÍÀàËÆÓÃ;µçÆ÷µÄÄþ¾²½áºÏ¼¤¹âºÍÇ¿ÁÒ¹âÔ´µÄÃÀÈݺÍÃÀÈÝ»¤ÀíÆ÷¾ßµÄÌØÊâÒªÇó Household and similar electrical appliances - Safety - Part 2-113: Particular requirements for cosmetic and beauty care appliances incorporating lasers and intense light sources |
IEC/EN60335-2-113 |
|
ÊÂÇéƵ¶Î/Frequency |
²âÊÔ³ß¶È |
µäÐͲúÎï Typical products |
|
FCC |
CE-RED |
||
2400MHZ-2483.5MHZ |
FCC part 15 |
EN300328 |
À¶ÑÀ£¬WLAN£¬ZIgBeeµÈ |
LTD band 1/3/7/8/20/22/28/33/34/38/40/42/43 |
½ûÓÃProhibited |
EN301 983-13 |
ÀûÓÃLTE¹¦Ð§´«ÊäÊý¾Ý Use LTE function to transfer data |
LTD band 2/4/5/7/12/13/17/41 |
FCC part 22 |
½ûÓÃ/Prohibited |
ÀûÓÃLTE¹¦Ð§´«ÊäÊý¾Ý Use LTE function to transfer data |
868MHZ |
½ûÓÃProhibited |
EN300 220 |
ÓÃASK¡¢FSKÀàµ÷ÖÆ´«ÊäÊý¾ÝÀàUse ASK, FSK function to transfer data |
433.92MHZ |
FCC part 15 |
EN300 220 |
ÓÃASK¡¢FSKÀàµ÷ÖÆ´«ÊäÊý¾ÝÀà Use ASK, FSK function to transfer data |
²âÊÔÀà±ð¼°ÒÀ¾Ý | ²âÊÔÏîÄ¿ |
¿É ¿¿ ÐÔ Reliability IEC 60068,IEC60529,IE60598 EIA-364.MIL-STD-202, ISO 4892,ISO 1431, ASTM G 154,ASTM G155, ASTM D4728, etc. |
ºãκãʪConstant Temprature and Humidity |
Õñ¶¯Vibration | |
ÑÎÎíSalt Spray | |
ζÈʪ¶ÈÑ»·Temprature & Humidity Cycling | |
ÊÙÃü·ÖÎöLife Analysi | |
³ôÑõÀÏ»¯Ozone Aging | |
·ÀË®·À³¾Waterproof and Dustproof | |
Õð¶¯&ζÈ&ʪ¶ÈVitration & Temprature & Humidity | |
¸ß¼ÓËÙÊÙÃüÊÔÑéHALT/HASS/HASA | |
ʧ Ч ·Ö Îö Óë Ô¤ ·À Failure Analysis and Prevention IPC/ECAJ-STD,IPCTM 650-2 iS016232-10,etc. |
PCB&PCBAʧЧ·ÖÎöºÍÆÀ¹À¡¢PCB& PCBA Analysis and Evaluation |
IC¿É¿¿ÐÔÉè¼Æ·ÖÎöReliability Design and Analysis of IC | |
ÎÞËð¼ì²âNon-destructive Testing | |
Í¿¶Æ²ãCoating and Palte Analysis | |
ÖÊÁÏÈÈѧMaterial Thermal | |
ÖÊÁÏÓ²¶ÈMateral Hardness | |
ɨÃèµç¾µÄÜÆ×·ÖÎöSEM-EDS |
¡ñ Èí¼þ²âÆÀ·þÎñÖ÷Òª°üÂÞ£ºÍ¨ÓÃÓ¦ÓÃÈí¼þ²âÆÀ¡¢APPÄþ¾²¼ì²â¡¢ÐÅÏ¢Äþ¾²·þÎñÈý¸ö²âÆÀ·þÎñÆ«Ïò¡£
The software evaluation service includes general software evaluation, APP security test , information security.
¡ñ GB/T 25000.51-2016¡¶ÏµÍ³ÓëÈí¼þ¹¤³ÌϵͳÓëÈí¼þÖÊÁ¿ÒªÇóºÍÆÀ¼Û£¨SQuaRE£©µÚ51²¿ÃÅ£º¾ÍÐ÷¿ÉÓÃÈí¼þ²úÎRUSP£©µÄÖÊÁ¿ÒªÇóºÍ²âÊÔϸÔò¡· IEC/ISO25051
System and software engineering -&nb
¾ßÌåÏêÇéÇë×ÉѯNG28ÔÚÏß¿Í·þ¡£